49 Point Checklist
General System Maintenance
- Name and Number Units (If Applicable). Note Any Existing Heating/Cooling Complaints
- Note Original Settings on Thermostat
- Test Thermostats
- Check Indoor Fan Operation Auto/On Modes
- Check Condition/Type of Return Filters
- Clean Filter Grill
- Note Outdoor Ambient Temperature
- Note Indoor Temperature
- Test Unit in Cooling and Record Temperature Splits
- Test Unit in Heating and Record Temperature Splits
- Observe System Operation
Indoor Air Handler Maintenance
- Inspect Exterior for Leaks, Oil and Water Stains, Condition of Insulation, etc.
- Inspect Refrigerant Piping & Gas Lines (if applicable) for Signs of Leaks
- Inspect Accessible Ductwork for Air Leaks and General Condition
- Inspect Disconnect and Wiring
- Tighten Electrical Connections/Fittings
- Check/Test Fan Motor Relay, Test Voltage Drop Across Relay
- Check Indoor Air Fan & Motor for Cleanliness, Clean Motor (If Applicable)
- Check Belts and Adjust Tension (If Applicable)
- Inspect Coil for General Condition & Oil Stains
- Inspect/Clean Inlet Side of Coil
- Inspect/Clean Condensate Pan
- Inspect/Clean Condensate Piping for P-Trap and Vent
- Inspect/Clean Overflow Condensate Pan
- Clear Condensate Lines with Nitrogen
- Test Condenser Fan Capacitor
- Check Amp Draw of Indoor Air Fan
- For Furnace Installations: Test Recirculated Air for CO2, Check/Clean Burners, Check/Clean Igniter, Check Flue Pipe
Outdoor Unit Maintenance
- Inspect Condensing Unit Externally for Signs of Leaks, Damage to Cabinet, etc.
- Inspect Refrigerant Piping and Condenser Areas for Signs of Leaks
- Inspect Disconnect and Wiring
- Inspect/Tighten Condenser Electrical Connections/Fittings
- Check/Test Main Contact Relay, Check for Voltage Drop Across Relay
- Check/Test Defrost Control Board (If Applicable)
- Clean Control Cabinet
- Inspect/Test Electrical Safety Circuits
- Inspect Condenser Fan Motor for Shaft Play, Fan Condition, Lubricate (If Applicable)
- Test Fan Capacitor
- Check Fan Motor Amp Draw
- Inspect Compressor Electrical Terminals, Crank Case Heater
- Test Compressor Run Capacitor
- Test Compressor Start Capacitor and Potential Relay
- Check Compressor Amp Draw
- Check Refrigerant Pressures (If Applicable)
- Ensure All Service Ports Are Capped and Tight
- Ensure All Service Valves Are Capped and Tight
- Inspect/Clean Condenser Coil with Water
- Clean Debris from Inside Cabinet
- Inspect/Repair Refrigerant Piping Insulation
Don’t Wait Until It’s Too Late!
FAQ
Common questions
What does the 49 point checklist cover?
Three parts of your system: general system maintenance (thermostats, filters, temperature splits and system operation), the indoor air handler (wiring, coils, condensate pans and lines, fan motor) and the outdoor unit (electrical connections, capacitors, compressor, refrigerant pressures and the condenser coil).
Is the 49 point checklist the same as preventative maintenance?
Yes. The 49 point checklist is what Service Smith's preventative maintenance visit covers. Why preventative maintenance matters.